Fire Sprinkler System Inspection and Testing

We offer Scheduled Preventative Maintenance for fire sprinkler systems, in accordance with NFPA 25 2017. We provide inspections and testing for all types of fire protection systems. Our Inspection Department utilizes a computer based program known as Building Reports. When we perform your fire sprinkler inspection you can be assured that your system is being inspected with integrity. Fire sprinkler systems is all about life safety. It is very important to maintain a sprinkler system. Please give us a call if you have any questions or concerns about your current sprinkler system. We will be more than happy to answer any questions we can for you!


Josh,
The testing days for my properties are my least favorite days...usually. My tenants, commercial and residential complain about the noise even when I notify them a month in advance so they can make arrangements to not be there! Eric and Keith were awesome and so professional yesterday and today. I appreciate IMMENSELY that they were able to silence any alarms so I did not have to hear my tenants complain, especially at the apartments. Thank you SO MUCH to your guys for making this a hassle free experience.
— Cristina Conte, Property Manager Conte Lubrano Apartments,LLC Conte Lubrano Office Building, LLC

What Makes Us Unique?

  • (2) Fire Protection Engineers ON STAFF

  • NICET Level III ITM Certified

  • 24-Hour Flexible Scheduling

  • Extensive Experience and Clearance

  • Quick Reporting Turnaround

  • Quality Assurance

  • Inspections with Integrity


How Often Should a Fire Sprinkler System Be Inspected and Tested?

Inspection Frequency - Per NFPA 25 2014 Edition

3.7.1* Frequency. Minimum and maximum time between
events.

  • 3.7.1.1 Daily Frequency. - Occurring every day.
  • 3.7.1.2 Weekly Frequency. - Occurring once per calendar week.

  • 3.7.1.3 Monthly Frequency. - Occurring once per calendar month.

  • 3.7.1.4 Quarterly Frequency. - Occurring four times per year with a minimum of 2 months and a maximum of 4 months.

  • 3.7.1.5 Semiannual Frequency. - Occurring twice per year with a minimum of 4 months and a maximum of 8 months.

  • 3.7.1.6 Annual Frequency. - Occurring once per year with a minimum of 9 months and a maximum of 15 months.

  • 3.7.1.7 Three Years Frequency. - Occurring once every 36 months with a minimum of 30 months and a maximum of 40 months.

  • 3.7.1.8 Five Years Frequency. - Occurring once every 60 months with a minimum of 54 months and a maximum of 66 months.


What Fire Protection Systems Do We Test?

  • Wet Systems
  • Dry Systems
  • Preaction Systems
  • Fire Pumps
  • Standpipe Systems
  • Private Fire Hydrants
  • Underground
  • Water Tanks
  • Backflows (via trusted subcontractor)
  • Fire Alarms (via trusted subcontractor)
  • Fire Extinguishers (via trusted subcontractor)

We Proudly Inspect and Test the Following States/Counties:

  • Maryland
    • Anne Arundel County
    • Baltimore County
    • Baltimore City
    • Calvert County
    • Charles County
    • Prince George's County
    • Montgomery County
    • Saint Mary's County
  • Virginia
    • Fairfax County
    • Arlington County
    • Prince William County
    • City of Alexandria
  • Washington, D.C.

Please contact us for inspections and testing! We would love to answer any questions you may have!

Name *
Name
Phone *
Phone

Micah Strickland - Vice-President / Service Manager

Contact Email: micah@stricklandfire.com


Tyler Jones - Inspections Department

Contact Email: tjones@stricklandfire.com